Now includes NABL Calibration Certificate.
The RIGOL MSO2102A is a 100 MHz mixed-signal oscilloscope designed for embedded-system debugging, digital circuit analysis, electronics development and production testing. It combines two analogue channels, 16 digital channels, up to 2 GSa/s analogue sampling, 14 Mpts standard analogue memory, fast waveform capture up to 52,000 wfms/s and hardware recording of up to 65,000 frames on an 8-inch colour display..
The RIGOL MSO2102A Mixed-Signal Oscilloscope is designed for engineers, technicians, research laboratories and educational institutions that need to analyse analogue and digital signals within the same time-correlated acquisition.
The oscilloscope provides two analogue channels with 100 MHz bandwidth and 16 digital logic channels through the supplied RPL2316 logic probe. This 2+16-channel configuration makes it suitable for debugging microcontrollers, FPGA designs, embedded controllers, digital buses, power electronics and mixed-signal circuits.
The MSO2102A uses RIGOL UltraVision technology to provide deep acquisition memory, waveform intensity grading, fast waveform capture and real-time waveform recording. It allows users to observe analogue waveform behaviour alongside digital logic activity, making it easier to identify timing relationships, communication errors and interactions between analogue and digital sections of a circuit.
The MSO2102A provides 100 MHz analogue bandwidth across two input channels.
It is suitable for analysing:
The calculated rise time is approximately 3.5 ns, which should be considered when measuring fast digital edges and short pulses.
The MSO2102A combines:
The digital channels are divided into two groups of eight channels. Each group can be configured with a separate logic threshold.
This mixed-signal configuration is useful for examining:
The analogue channels provide:
The high real-time sampling rate provides more acquisition points across waveform transitions, helping users observe signal shape, overshoot, ringing, noise and intermittent abnormalities.
The analogue peak-detect function can capture pulses as narrow as:
Digital sampling depends on the number of active logic channels:
The digital peak-detect capability is approximately:
The minimum detectable digital pulse width is approximately 5 ns.
These specifications make the MSO2102A suitable for general embedded and digital logic analysis, but the digital channels should not be described as providing 2 GSa/s sampling.
The MSO2102A provides 14 Mpts standard analogue memory in single-channel operation.
Standard analogue memory allocation:
The optional memory licence expands analogue memory to:
Deep memory allows users to capture longer waveform intervals while retaining a useful sampling rate.
It is beneficial for:
The 56 Mpts memory depth should be listed as optional unless the appropriate licence is installed.
Digital memory is allocated according to the number of active digital channels.
Standard digital memory:
Optional digital memory:
This memory supports longer digital captures for logic analysis, parallel bus evaluation and embedded-system debugging.
The MSO2102A provides a maximum waveform capture rate of up to 52,000 waveforms per second in dots-display mode.
Fast waveform acquisition improves the probability of detecting rare signal events such as:
The display supports up to 256 levels of intensity grading, helping distinguish frequently occurring waveform activity from occasional events.
The oscilloscope supports hardware waveform recording, playback and analysis.
Maximum recording depth:
Waveform recording allows users to:
The reduction in maximum frame count when digital channels are enabled should be considered when planning long mixed-signal recording sessions.
The MSO2102A provides analogue vertical sensitivity from:
This wide vertical range supports measurements of:
The 500 µV/div range uses digital amplification based on the 1 mV/div setting and should be considered accordingly during precision measurements.
The analogue inputs support:
Maximum permitted input voltage differs between the two impedance settings. Users must select suitable probes and observe the input voltage limits stated in the product manual.
The digital channels support predefined and user-adjustable logic thresholds.
Available logic families include:
The user-defined threshold range is approximately ±20 V in 10 mV steps.
This allows the logic analyser to work with several digital voltage standards used in embedded and industrial electronics.
The MSO2102A includes several trigger modes for isolating specific analogue and digital events.
Standard trigger functions include:
Optional advanced trigger functions include:
The optional functions require the applicable software licences.
The MSO2102A supports serial protocol triggering and decoding across analogue and digital channels.
Supported buses include:
Parallel bus decoding is included as a standard function. RS232/UART, I2C, SPI and CAN decoding may require the relevant licences, depending on the supplied configuration.
Protocol analysis allows users to:
Up to two decoded buses can be displayed.
The MSO2102A provides automatic measurements for both analogue and digital channels.
Analogue measurement categories include:
Digital measurements include:
Up to five measurements can be displayed at the same time. Statistical functions include current, average, maximum, minimum, standard deviation and measurement count.
The oscilloscope includes mathematical and frequency-domain analysis functions.
Available functions include:
FFT analysis is useful for:
Mask-based pass/fail testing allows users to compare acquired waveforms with predefined tolerance limits.
It can support:
The AUX output can provide a trigger or pass/fail pulse for integration with external test systems.
The MSO2102A uses an 8-inch TFT colour display with 800 × 480 pixel resolution.
Display functions include:
The display can show analogue waveforms, digital logic channels, measurements and decoded communication data together.
The MSO2102A supports computer communication, laboratory networking and automated testing.
Connectivity includes:
Remote programming and waveform transfer support automated production testing, repetitive validation and laboratory data collection.
The MSO2102A does not include an integrated arbitrary waveform generator.
A dual-channel 25 MHz waveform generator is available only in the MSO2102A-S model.
Users who require integrated waveform generation should select the “-S” model rather than the standard MSO2102A.
The RIGOL MSO2102A is suitable for:
RevineTech supplies professional test and measurement equipment for electronics development, research, production, education and industrial testing.
Technical selection assistance can include:
The MSO2102A provides 100 MHz bandwidth across two analogue channels.
It supports:
The oscilloscope combines:
Analogue sample rates include:
Digital sample rates include:
Analogue memory includes:
Digital memory includes:
Fast acquisition helps locate:
Recording capability includes:
Supported digital threshold types include:
Supported protocol functions include:
Applicable software licences should be confirmed before ordering.
The low vertical scale helps analyse:
The oscilloscope supports up to 12-bit high-resolution processing under specified time-base and sample-rate settings.
Built-in analysis supports:
Display features include:
Interfaces include:
| Specification | RIGOL MSO2102A |
|---|---|
| Product series | RIGOL MSO2000A Series |
| Product type | Mixed-signal oscilloscope |
| Analogue bandwidth | 100 MHz |
| Analogue channels | 2 |
| Digital channels | 16 |
| Built-in waveform generator | No |
| Maximum analogue sample rate | 2 GSa/s |
| Maximum digital sample rate | 1 GSa/s with eight channels |
| Standard analogue memory | 14 Mpts single-channel |
| Optional analogue memory | 56 Mpts single-channel |
| Standard digital memory | 14 Mpts with eight digital channels |
| Optional digital memory | 28 Mpts with eight digital channels |
| Maximum waveform capture | Up to 52,000 wfms/s |
| Maximum waveform recording | 65,000 frames with digital channels off |
| Analogue vertical resolution | 8 bits |
| High-resolution processing | Up to 12 bits under specified conditions |
| Digital vertical resolution | 1 bit |
| Minimum analogue scale | 500 µV/div |
| Typical calculated rise time | 3.5 ns |
| Display | 8-inch TFT colour display |
| Display resolution | 800 × 480 pixels |
| Active Analogue Channels | Maximum Sample Rate | Standard Memory | Optional Memory |
| One channel | 2 GSa/s | 14 Mpts | 56 Mpts |
| Two channels | 1 GSa/s per channel | 7 Mpts per channel | 28 Mpts per channel |
| Active Digital Channels | Maximum Sample Rate | Standard Memory | Optional Memory |
| Up to 8 channels | 1 GSa/s | 14 Mpts | 28 Mpts |
| 16 channels | 500 MSa/s | 7 Mpts | 14 Mpts |
| Specification | Details |
| Input coupling | AC, DC or GND |
| Input impedance | 1 MΩ ±1% with 19 pF ±3 pF, or 50 Ω ±1.5% |
| Vertical resolution | 8 bits |
| High-resolution mode | Up to 12 bits under specified settings |
| Vertical scale at 1 MΩ | 500 µV/div to 10 V/div |
| Vertical scale at 50 Ω | 500 µV/div to 1 V/div |
| Bandwidth limit | 20 MHz |
| DC gain accuracy | ±2% full scale |
| Channel isolation | Greater than 40 dB |
| Probe attenuation | 0.01X to 1000X |
| Maximum input at 1 MΩ | CAT I 300 Vrms or CAT II 100 Vrms, subject to specified limits |
| Specification | Details |
| Number of channels | 16 |
| Logic probe | RPL2316 |
| Sample rate with 8 channels | 1 GSa/s |
| Sample rate with 16 channels | 500 MSa/s |
| Minimum detectable pulse width | Approximately 5 ns |
| Input impedance | Approximately 101 kΩ |
| Probe loading | Approximately 8 pF |
| Threshold range | ±20 V in 10 mV steps |
| Minimum voltage swing | 500 mVpp |
| Vertical resolution | 1 bit |
| Threshold groups | Two groups of eight channels |
| Specification | Details |
| Sampling mode | Real-time |
| Time-base range | 5 ns/div to 1 ks/div |
| Time-base accuracy | ≤±15 ppm |
| Time-base drift | ≤±5 ppm per year |
| Acquisition modes | Normal, Average, Peak Detect and High Resolution |
| Average settings | 2 to 8192 acquisitions |
| Analogue peak detection | 500 ps single-channel, 1 ns dual-channel |
| Digital peak detection | 1 ns with eight channels, 2 ns with 16 channels |
| Maximum waveform capture | 52,000 wfms/s |
| Display modes | Y-T, X-Y and Roll |
| Configuration | Maximum Recorded Frames |
| Digital channels disabled | Up to 65,000 |
| Digital channels enabled | Up to 32,000 |
| Availability | Trigger Modes |
| Standard | Edge, Pulse, Slope, Pattern, Runt, Setup/Hold and standard video |
| Standard bus triggers | RS232/UART, I2C and SPI |
| Optional advanced triggers | Window, Nth Edge, HDTV, Delay, Timeout, Duration and USB |
| Optional automotive trigger | CAN |
| Trigger modes | Auto, Normal and Single |
| Trigger holdoff | 100 ns to 10 s |
| Trigger sources | Analogue channels, digital channels, EXT and AC Line, depending on trigger type |
| Availability | Supported Functions |
| Standard decoding | Parallel bus |
| Optional serial decoding | RS232/UART, I2C and SPI |
| Optional automotive analysis | CAN |
| Maximum decoded buses displayed | 2 |
| Analogue and digital correlation | Supported |
| Function | Capability |
| Analogue automatic measurements | Voltage, timing, frequency, pulse, phase and delay |
| Digital automatic measurements | Frequency, period, pulse width, duty cycle, phase and delay |
| Simultaneous measurements | Up to 5 |
| Measurement statistics | Current, average, maximum, minimum, standard deviation and count |
| Frequency counter | Six-digit hardware counter |
| Cursor measurements | Manual, tracking and automatic |
| FFT | Frequency-domain analysis |
| Waveform mathematics | Arithmetic, logic and advanced functions |
| Digital filtering | Supported |
| Mask testing | Pass/fail testing |
| Reference waveforms | Supported |
| Waveform recording | Up to 65,000 frames |
| Specification | Details |
| Display size | 8 inches |
| Display type | TFT LCD |
| Display resolution | 800 × 480 pixels |
| Display colours | 160,000 |
| Intensity grading | Up to 256 levels |
| Display modes | Dots and vectors |
| Persistence | 50 ms to infinite |
| Real-time clock | Supported |
| Interface | Function |
| USB Host | External storage and supported peripherals |
| USB Device | Computer communication |
| LAN | Network communication |
| LXI | Automated test integration |
| AUX OUT | Trigger or pass/fail output |
| USB-GPIB | Optional legacy test-system connection |
| Remote programming | Supported through compatible software and commands |
| Specification | Details |
| Dimensions | 361.6 × 179.6 × 130.8 mm |
| Weight | Approximately 3.9 kg without packaging |
| Maximum power consumption | 50 W |
| Input power | 100 V to 240 V, 45 Hz to 440 Hz |
| Operating temperature | 0°C to 50°C |
| Maximum operating altitude | 3,000 metres |
| Recommended calibration interval | 18 months |
Your enquiry has been submitted successfully.